PAC30A-SERIES Ximaden SCR PAC30A-YT-60A

$242.85$268.56

Tag:

Description

PAC30A-SERIES Beijing XIMADEN original factory straight hair XIMADEN SCR PAC30A-YT-60A

PAC30A-YT-60A center is not grounded
PAC30A-YT-60A KR center is not grounded to speed up melting
PAC30A-YN-60A center point grounding
PAC30A-YN-60A KR center point grounding acceleration

Three-phase power regulator>PAC30A series European style three-phase power regulator and voltage regulator integrated power regulator
European style safe and dustproof structure. Beautiful and elegant.
Red, green and blue LED lights. The working status is clear at a glance, making it a reliable choice for purely resistive loads.
Manually given signal
DCO-5v
automatic control signal
(Can be adjusted according to customer needs) 4~-20nA. Input impedance 120Q; sampling time > 50 times/second
Fan power supply
220VAC50H billion
resolution
Adjust output 0.2*
The output voltage
0-95% of input voltage;
output
control method
The factory default is voltage regulation. If you want to integrate voltage regulation and power regulation, special instructions are required when ordering.
Alarm Output
Relay alarm output AL1, AL2 alarm contacts. Capacity 240VAC 2A (pure group)
load
Three-phase 38OVAC 50HZ pure resistive/inductive load
illustrate,
1 The star center is not grounded or the outer triangle is 2) The star center is grounded 3) Three-phase half-controlled rectifier bridge
1. The rated current in the above table is based on pure resistive load.
Get up slowly. slow stop
The slow-on time is set by the internal potentiometer P3 (0.2~120 seconds) and the slow-off time is fixed at 3 seconds.
example. Such as transformer load or other special load
Emergency stop and automatic slow start
Emergency stop due to instantaneous phase loss during operation (<20ms), automatic slow start after power on (cancelled when three phases are missing and one is missing)
Please leave more margin.
Protect
2. The factory setting load wiring mode is that the center is not connected.
Over temperature protection
When the radiator temperature is higher than 8O℃, the output is prohibited and the alarm occurs.
Ground, if center grounding is required, please specify when ordering
Load overcurrent protection
Alarm and prohibit output (cannot replace quick fuse)
illustrate.
Installation Environment
Wall-mounted vertical installation. good ventilate. Not subject to direct sunlight or heat radiation. Non-corrosive and non-flammable
3. Options. Adding module current control XCT1 requires special
Usage environment
high humidity
In high temperature, high humidity and altitudes greater than 1,000 meters, derating should be used. Ambient relative humidity: 906
Special explanation.
temperature
-10℃~+55’℃

PAC30A-SERIES Ximaden SCR PAC30A-YT-60A
PAC30A-SERIES Ximaden SCR PAC30A-YT-60A
PAC30A-SERIES Ximaden SCR PAC30A-YT-60A

Additional information

Weight 1 kg
sort by color

PAC30A-YT-60A center is not grounded, PAC30A-YT-60A KR center is not grounded to speed up melting, PAC30A-YN-60A center point grounding, PAC30A-YN-60A KR center point grounding acceleration

Reviews

There are no reviews yet.

Be the first to review “PAC30A-SERIES Ximaden SCR PAC30A-YT-60A”